TRANE R-454B IntelliCoreTM Split Systems User Guide (2025)

TRANE R-454B IntelliCoreTM Split Systems User Guide (1)

TRANE R-454B IntelliCoreTM Split Systems

TRANE R-454B IntelliCoreTM Split Systems User Guide (2)

FAQs

  • Q: Who should handle the installation and servicing of this equipment?
    • A: Only qualified personnel should install and service the equipment to prevent accidents and ensure proper operation.
  • Q: What precautions should be taken when working on the equipment?
    • A: Always observe all safety advisories provided in the manual and on equipment labels. Wear appropriate PPE, follow proper field wiring guidelines, and be cautious with refrigerant handling.
  • Q: Is it necessary to recover refrigerant before servicing the system?
    • A: Yes, it is crucial to recover refrigerant to relieve pressure and prevent potential hazards such as explosions or equipment damage.

SAFETY WARNING

Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and require specific knowledge and training. Improperly installed, adjusted, or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment.

Introduction

Read this manual thoroughly before operating or servicing this unit.Warnings, Cautions, and NoticesSafety advisories appear throughout this manual as required. Your safety and the proper operation of this machine depend upon the strict observance of these precautions.The three types of advisories are defined as follows:

  • WARNING
    • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • CAUTION
    • Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices.
  • NOTICE
    • Indicates a situation that could result in equipment or property damage only accidents.
Important Environmental ConcernsScientific research has shown that certain man-made chemicals can affect the earth’s naturally occurring stratospheric ozone layer when released into the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine, and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine, and Carbon (HCFCs). Not all refrigerants containing these compounds have the same potential impact on the environment. Trane advocates the responsible handling of all refrigerants.Important Responsible Refrigerant PracticesTrane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified according to local rules. For the USA, the Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering, and recycling certain refrigerants and the equipment that is used in these service procedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them.WARNINGProper Field Wiring and Grounding Required!Failure to follow the code could result in death or serious injury. All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state/national electrical codes.WARNINGPersonal Protective Equipment (PPE) Required!Failure to wear proper PPE for the job being undertaken could result in death or serious injury. Technicians, to protect themselves from potential electrical, mechanical, and chemical hazards, MUST follow precautions in this manual and on the tags, stickers, and labels, as well as the instructions below:
  • Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut-resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE, and arc flash clothing). ALWAYS refer to appropriate Safety Data Sheets (SDS) and OSHA guidelines for proper PPE.
  • When working with or around hazardous chemicals, ALWAYS refer to the appropriate SDS and OSHA/GHS (Global Harmonized System of Classification and Labelling of Chemicals) guidelines for information on allowable personal exposure levels, proper respiratory protection, and handling instructions.
  • If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPE by OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, beforeservicing the unit. NEVER PERFORM ANY SWITCHING, DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR THE INTENDED VOLTAGE.
WARNINGRefrigerant under High Pressure!Failure to follow the instructions below could result in an explosion which could result in death serious injury or equipment damage. The system contains refrigerant under high pressure. Recover refrigerant to relieve pressure before opening the system. See unit nameplate for refrigerant type. Do not use non-approved refrigerants, refrigerant substitutes, or refrigerant additives.WARNINGExplosion Hazard!Failure to follow the instructions below could result in an explosion which could result in death or serious injury, and equipment damage. NEVER bypass system safeties to pump down the unit component's refrigerant into the microchannel heat exchanger (MCHE) coil. Do NOT depress the compressor contactor since it effectively bypasses the high-pressure control.CopyrightThis document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.TrademarksAll trademarks referenced in this document are the trademarks of their respective owners.

Overview

Trane’s RAUK 20- through 120-ton condensing unit product line is designed for use only with R–454B and POE oil. R–454B is a higher-pressure refrigerant that requires the other components of the system to be rated for the higher pressures. For compressor lubrication, the refrigerant requires POE oil. Traditionally, refrigerant piping practices were guided by four principles:

  • Return the oil to the compressor.
  • Maintain a column of liquid at the expansion valve.
  • Minimize the loss of capacity.
  • Minimize the refrigerant charge in the system.
Evidence accumulated over years of observation demonstrates that the lower the refrigerant charge, the more reliably a split air-conditioning system performs. Any amount of refrigerant over the minimum design charge becomes difficult to manage. The excess refrigerant tends to collect in areas that can interfere with proper operation and eventually shorten the service life of the system. To successfully minimize the system refrigerant charge, the correct line size should be used and the line length must be kept to a minimum.BackgroundIn a split air-conditioning system, the four major components of the refrigeration system are connected by field-assembled refrigerant piping. A vapor or gas line connects the evaporator to the compressor, the discharge line connects the compressor to the condenser, and the liquid line connects the condenser to the expansion device, which is located near the evaporator inlet. Operational problems can occur if these refrigerant lines are designed or installed improperly.TRANE R-454B IntelliCoreTM Split Systems User Guide (3)The origin of the requirements for equivalent line lengths of components, line pressure drop, and minimum and maximum refrigerant velocities is uncertain. It appears likely that at least some of the supporting data was derived from measurements and/or equations involving water. Some resource materials even show water components when illustrating refrigerant piping requirements. Subsequent reviews of analytical and empirical data for refrigerant piping resulted in the publication of two research papers: Pressure Losses in Tubing, Pipe, and Fittings by R.J.S. Pigott and Refrigerant Piping Systems — Refrigerants 12, 22, 500 by the American Society of Refrigeration Engineers (ASRE). In his paper, Pigott described his use of refrigerant as the fluid and his direct measurement of pressure drops. His findings indicated that the pressure drop of many line components is small and difficult to measure. For these components, he used experimental data to derive a formula relating the geometry of the component to its pressure drop. Overall, his calculated pressure loss of the components was less than originally determined.The conclusion of the ASRE research paper stated that the minimum required velocity to maintain oil entrainment in vertical risers and horizontal lines will vary with the diameter of the tube and with the saturation temperature of the suction gas. In other words, the minimum required velocity for oil entrainment is not constant.Updated GuidelinesLiquid LinesHistorically, liquid lines were sized to minimize the pressure losses within the piping circuit. Oil movement through the piping wasn’t a concern (nor is it today) because oil is miscible in liquid refrigerant at normal liquid-line temperatures. The historic and traditional 6 psi liquid line pressure drop had the unintended consequence of requiring line sizes with large internal refrigerant volumes. With R-454B refrigerant and POE oil, this pressure drop can be as high as 50 psi. Within these guidelines, refrigeration operation is maintained while minimizing the refrigerant charge. It is still required to limit the liquid line velocity to 600 ft/min to help avoid issues with the water hammer.Suction LinesR-454B is a high-pressure refrigerant and allows higher-pressure drops in the suction lines. With R-454B refrigerant, that same 2°F loss is a 5 psi drop. Additional pressure drops may be tolerated in certain applications. R-454B refrigerant suction lines must be sized to maintain oil-entrainment velocities in both the horizontal and vertical risers. Oil entrainment for R-454B is based on suction temperature as well as tube diameter. Trane has used ASHRAE data to create equation-based formulas to predict the entrainment velocities of R-454B refrigerant and POE oil. These minimum velocities are reflected in the line sizes listed in the component selection summary Table 1.Equipment PlacementMinimize Distance Between ComponentsFor a split air-conditioning system to perform as reliably and inexpensively as possible, the refrigerant charge must be kept to a minimum. To help accomplish this design goal:
  • Site the outdoor unit (cooling-only condensing unit or heat pump) as close to the indoor unit as possible.
  • Route each interconnecting refrigerant line by the shortest and most direct path so that line lengths and riser heights are no longer than necessary.
  • Use only horizontal and vertical piping configurations.
  • Determine whether the total length of each refrigerant line requires Trane review. Be sure to account for the difference in elevations of the indoor and outdoor units when calculating the total line length.
Interconnecting lines of 150 lineal ft (45.7 m) or less that comply with the figures in the following section do not require Trane's review. Reference the following section for the maximum liquid and suction riser elevation.TRANE R-454B IntelliCoreTM Split Systems User Guide (4)Notes:
  • Regardless of orientation, hot gas bypass (HGBP) lines are limited to 75 feet. See Hot Gas Bypass Installation Guideline for Direct Expansion (DX) Equipment APP-APG017*-EN for more details.
  • In Figure 3, the total pipe length is 126 feet. This is plotted across the bottom of Figure 2,and Figure 4. The red line represents suction and liquid lines. As it is assumed they are piped side by side, only one line is shown for simplicity.
  • When evaluating Figure 2, all liquid lines and suction drops are ignored. In the Piping Example, three 10-foot sections of the action pipe flow upwards. This is a suction line lift of 30 feet. Plotting the total line length of 126 feet on the horizontal axis of Figure 2, and plotting the 30 feet of suction lift on the vertical axis of Figure 2, the final result is in the dark shaded area of Figure 2. This complies with Figure 2, The user can use the line sizes in Table 1,
  • When evaluating Figure 4, all suction lines and liquid drops are ignored. In the Piping Example, two 10-foot liquid lines are flowing upwards. This is a liquid line lift of 20 feet. Plotting the total line length of 126 feet on the horizontal axis of Figure 4, and plotting the 20 feet of liquid lift on the vertical axis of Figure 4, The final result is in the dark shaded area of Figure 4, This complies with Figure 4, The user can use the line sizes in Table 1.TRANE R-454B IntelliCoreTM Split Systems User Guide (5)TRANE R-454B IntelliCoreTM Split Systems User Guide (6)
Line Sizing, Routing, and Component SelectionThe figure below illustrates an example of an RAUK split-system component arrangement. Use it to determine the proper, relative sequence of the components in the refrigerant lines that connect the RAUK condensing unit to an evaporator coil. Refer to “Examples of Field-Installed Evaporator Piping,” for more detailed schematics of evaporator piping. The RAUK units are R-454B machines, and all the selected components installed in the field must also be rated for use with R-454B.TRANE R-454B IntelliCoreTM Split Systems User Guide (7)Notes:
  1. Shutoff valves are a field-installed option and no longer come standard from the factory. Field-installed shutoff valves should have an integral access port.
  2. RAUK condensing units ship with three integral access ports. Each TXV requires an additional field-installed access port installed between the TXV and sight glass.
  3. A field-installed access port is also required at each evaporator suction line.
Liquid LinesLine SizingProperly sizing the liquid line is critical to a reliable split-system application. Table 1, shows the recommended liquid-line sizing for each RAUK model based on its nominal capacity. Using the preselected tube diameter to uniform size the liquid line will maintain operating requirements and is the line size around which the RAUK installation literature charging charts were generated. Increasing the line size will not increase the allowable line length.RoutingInstall the liquid line with a slight slope in the direction of flow so that it can be routed with the suction line. Due to the normal force of gravity, there is a maximum liquid riser height limitation. As the liquid riser grows in height, gravity produces a pressure drop that may result in a loss of subcooling. Figure 2, and Figure 4, show the permissible rise in the liquid line (without excessive loss of subcooling). System designs outside the application envelope of the unit require Trane's review. The RAUK unit design includes a liquid line check/relief assembly at the outlet of the sub-cooler to prevent liquid refrigerant from being drawn back to the compressor during the off-cycle. The relief valve discharges to the condenser to prevent excessive pressures from developing in the liquid line during the off cycle, due to a temperature change of the trapped column of liquid between the solenoid valve and check valve.InsulationThe liquid line is generally warmer than the surrounding air, so it does not require insulation. Heat loss from the liquid line improves system capacity because it provides additional subcooling. If the liquid line is routed through a high-temperature area, such as an attic or mechanical room, insulation would be required.ComponentsLiquid-line refrigerant components necessary for a successful job include a filter drier, access port, solenoid valve, moisture-indicating sight glass, expansion valve(s), and ball shutoff valves. Figure 5, illustrates how to sequence the components properly in the liquid line. Position the components as close to the evaporator as possible. Table 1, identifies suitable components, by part number, for each RAUK model. Note that there are two access ports: one located at the RAUK and one located at the evaporator.“Parts,” lists suitable expansion valves.Liquid Filter DrierThere is no substitute for cleanliness during system installation. The liquid filter drier prevents residual contaminants, introduced during installation, from entering the expansion valve and solenoid valve. If choosing a filter other than the one listed in “Parts, make sure its volume, filtering, and moisture-absorbing characteristics are equivalent, and that it is the replaceable core type.Access PortThe access port located at the RAUK allows the unit to be charged with liquid refrigerant and is used to determine the charge level. This port is usually a Schraeder valve with a core.Solenoid ValveIn RAUK split systems with MCHE, solenoid valves isolate the refrigerant from the evaporator during the off cycles. Trim solenoids cannot be used with MCHE (refer to “Microchannel Heat Exchanger Condensers,”).Note: RAUK units with MCHE no longer employ pump-down, but refrigerant isolation solenoids are required. The suggested solenoid uses a 120-volt service and requires code-compliant wiring to the RAUK condensing unit. For more information, see “Microchannel Heat Exchanger Condensers,”Moisture-Indicating SightglassBe sure to install one moisture-indicating sight glass in the main liquid line.Note: The sole value of the glass is its moisture-indicating ability. Use the Installation manual charging curves—not the sight glass—to determine proper charge levels. A properly charged RAUK unit may show bubbles in the sight glass.Expansion ValveThe expansion valve is the throttling device that meters the refrigerant into the evaporator coil. Metering too much refrigerant floods the compressor; metering too little elevates the compressor temperature. Choosing the correct size and type of expansion valve is critical to ensure that it will correctly meter refrigerant into the evaporator coil throughout the entire operating envelope of the system. Correct refrigerant distribution into the coil requires an expansion valve for each distributor. For improved modulation, choose expansion valves with balanced port construction and external equalization.“Parts,” identifies the part numbers of the valves suggested for commercial RAUK MCHE systems. The tonnage of the valve should represent the tonnage of the portion of the coil that the TXV/distributor will feed. IntelliCore™ with microchannel condenser coils with fin and tube evaporators require a TXV with a bleed port to prevent high-pressure control trips.Ball Shutoff ValvesAdding manual, ball-type shutoff valves upstream and downstream of the filter simplifies the replacement of the filter core. Table 1 lists only one of the numerous manufacturers of these valves. If you choose a valve from another manufacturer, ensure that its specifications are equivalent to the valve identified in this guide. Angle valves may be substituted for liquid line ball valves. Refer to Table 1, Component selection summary.Gas Line Line SizingProper line sizing is required to guarantee that the oil returns to the compressor throughout the system’s operating envelope. At the same time, the line must be sized so that the pressure drop does not excessively affect capacity or efficiency. To accomplish both objectives, it may be necessary to use two different line diameters: one for the horizontal run and the vertical drops, and another for the vertical lifts (risers).Note: Preselected suction-line diameters are shown in Table 1, and are independent of the total line length for properly charged 20 to 120-ton RAUK units in normal air-conditioning applications.RoutingRoute the line as straight (horizontally and vertically) as possible. Avoid unnecessary changes of direction. To prevent residual or condensed refrigerant from “free-flowing” toward the compressor, install the gas line so that it slopes by ¼ to 1 inch per 10 feet of run (1 cm per 3 m) toward the indoor coil. Do not install suction riser oil traps. With field-supplied air-handler coils, what appears to be a riser trap is located at the coil outlet. This is a DETINT. See Figure 6, for an example. This piping arrangement is the result of two requirements:
  • Drain the coil to the common low point.
  • Preventing any off-cycle condensed refrigerant in the coil from attempting to flow to the compressor. Double suction risers MUST NOT be installed. All 6 – 25 ton TTA and TWA units unload such that a single gas line size, preselected in the Component Selection tables found in Table 1, provides sufficient velocity to return oil up the permissible riser height.
Note: If a gas riser is properly sized, the oil will return to the compressor regardless of whether a trap is present. If a gas riser is oversized, adding a trap will not restore proper oil entrainment, and may damage the compressor.TRANE R-454B IntelliCoreTM Split Systems User Guide (8)DETENTThe riser DETINT (Double-Elbow That Is Not a Trap) does not retain oil during unit operation. When the unit is off, the DETINT prevents liquid oil or refrigerant from draining in either direction. It also allows sub-cooled oil and liquid refrigerant to drain past the TXV bulb. This promotes stable TXV operation. The DETINT riser should be extended above the AHU. It may then continue up, down, or side to side in any direction.Avoid Underground Refrigerant LinesUnderground lines create risk due to refrigerant condensing during the off cycle, groundwater migration, damage from wildlife, expansion, and contraction, service access, and abrasion/corrosion. These hazards can quickly impair reliability. Installation of underground refrigerant lines is deemed an installation error. It is difficult to separate underground piping installation damage from manufacturing defects. Compressor damage may not be covered under the manufacturer's defect warranty.InsulationAny heat that transfers from the surrounding air to the cooler suction lines increases the load on the condenser (reducing the system’s air-conditioning capacity) and promotes condensate formation. After operating the system and testing all fittings and joints to verify that the system is leak-free, insulate suction lines to prevent heat gain and unwanted condensation.ComponentsThe suction line requires field installation of these components: a filter, access port, Frostat™ control for coil frost protection, and ball shutoff valve. Position them as close to the compressor as possible. Table 1, identifies suitable components by part number for each RAUK model.Note: The placement of the Frostat control is illustrated in Figure 5FilterThe suction filter prevents contaminants, introduced during installation, from entering the compressor. For this reason, the suction filter should be the replaceable core type and a clean core should be installed after the system is cleaned up. To prevent oil logging, confirm the filter is oriented to a free drain. Table 1, lists only one of the many manufacturers of suction-line filters. If you choose a filter from another manufacturer, ensure that its capability and volume are equivalent to the suction filter identified in this guide.Access PortThe access port is used to determine suction pressure. This port is usually a Schraeder valve with a core.Service ValveService Valves may be convenient for servicing the condensing unit. However, they may not be used for pump-down refrigerate isolation. If a field-installed service valve is added to the system, it must be a full port and should have a factory-installed access port.Frostat DX Fin Tube Coil Frost ProtectionThe Frostat™ control is the preferred method for protecting the evaporator coils from freezing on typical comfort cooling applications. It senses the suction-line temperature and temporarily disables mechanical cooling if it detects frost conditions. The control is mechanically attached to the outside of the refrigerant line, near the evaporator, and wired to the unit control panel. A Frostat is recommended for each Condensing Unit Circuit.Ball Shutoff ValveAdding manual, ball-type shutoff valves upstream and downstream of the filter simplifies the replacement of the filter core. Table 1, lists only one of the numerous manufacturers of these valves. If you choose a valve from another manufacturer, ensure that its specifications are equivalent to the valve identified in this guide.Solenoid Isolation ValvesRAUK condensing units use bleed port TXVs. Solenoid isolation valves should be installed to prevent refrigerant migration when the unit is off. The solenoid isolation valves should not be used for capacity control or refrigerate refrigeration.Expansion ValvesExpansion valves meter refrigerant into the evaporator under controlled conditions. If there is too much refrigerant, the refrigerant will not completely vaporize and the remaining liquid will slug the compressor. If there is too little refrigerant, there may not be enough cooling for the compressor.There are two types of valves:
  • Standard valves are used on the RAUK MCHE systems with brazing plate chilled-water evaporators.
  • Bleed port valves are used on RAUK MCHE systems with fin tube DX evaporators. They have an internal port that shunts the refrigerant around the modulating portion of the valve. , AND list the correct expansion valves. Each evaporator distributor requires a dedicated expansion valve to maintain proper coil distribution. The expansion valve should be selected to match the capacity of the coil that the distributor feeds.
Example: 20 tons coil with two equal distributors20 / 2 = 10Each TXV should be selected for 10 tons.Occasionally, the coil or distributors have a difference of only one circuit tube. This may result in different-sized evaporator distributors. However, this difference is negligible, and the difference should be ignored. The proper balance for feeding refrigerant for a RAUK system is to provide 18°F of superheat—the difference between the saturated and actual refrigerant temperature leaving the evaporator. On bleed port valves, the expansion valve superheat is set high by the manufacturer. These valves will need to be adjusted to 18°F superheat.

Controls

The RAUK unit is available with different control options. These control options include No System Control, Supply Air VAV, and EVP Control. The No System Control option is often selected when a controls contractor wants to stage the RAUK compressors. For details regarding Symbio™ 800 control sequence of operation, please refer to IntelliCore™ Split System Installation, Operation, and Maintenance (SS-SVX091*,-EN) or IntelliCore™ Split System Product Catalog (ACDS-PRC005*-EN).

Hot Gas Bypass

Hot gas bypass (HGBP) is added to HVAC systems to correct several operational problems. Unfortunately, the practice will increase energy consumption and may decrease reliability. Trane has more than 15 years of experience in the successful use of systems without hot gas bypass in commercial comfort-cooling applications. To prevent evaporator freeze-up, the installed AHUs require Trane Frostat™ coil frost protection. Like hot gas bypass, the Frostat system protects the coil from freezing, but it does so by turning off compressors when the Frostat sensor detects the conditions suitable for evaporator coil frosting. The compressor is released to operate when the coil temperature rises a few degrees above the frost threshold. The Frostat control strategy reduces the overall energy consumption of the system while maintaining system control. This method is often all that is required for standard comfort cooling. The amount of HGBP allowed is limited by Energy Codes such as ASHRAE 90.1, the IEEC, and California Title 24. Units less than 20 tons may use up to 10% HGBP. Units 20 tons and larger may use up to 15% HGBP.Because of the lower evaporator entering air conditions, HGBP is almost always required for 100% OA systems. HGBP may also be beneficial for systems with tighter humidity or discharge air requirements. When using HGBP, the total "linear" line length should be limited to 75 feet. Field-installed oil separators are not 100% efficient and may not have an oil recovery cycle. An oil separator may not be used to extend HGBP lines beyond 75 feet. Liquid line bypass mixed with hot gas and routed to the suction line is an alternative form of HGBP. This goes by various trade names, such as "APR". While these devices may offer a lower cost installation, theoretical performance is the same as traditional HGBP. These devices are also limited to 75 feet of total system line length.Chilled-Water SystemsChilled-water systems may require HGBP because of widely and quickly varying loads. Chilled-water comfort cooling applications, however, seldom need HGBP. One way to mitigate the necessity of HGBP is to include a supply tank that has five-minute storage. In all cases, the loop time of the system should be five minutes.Additional Resources

  • Refer to the Trane Application Guide "Hot Gas Bypass Installation Guideline for Direct Expansion (DX) Equipment” (APP-APG017*- EN) for more information such as design, pipe size, and maximum hot gas bypass length.
  • Refer to the Engineers Newsletter, “Hot Gas Bypass – Blessing or a Curse?” (ADM-APN007*-EN).
Remodel, Retrofit, or ReplacementInevitably, older condensing unit/evaporator systems that are designed for use with a refrigerant other than R-454B will need to be upgraded. As of this document, current building codes and EPA regulations do not permit mixing and matching any components designed for an A1 refrigerant, such as R-410A with any components designed for an A2L refrigerant such as R-454B. This includes air-handling unit components. Should the installer replace any A1 system with one containing A2Ls, the installer must also confirm that all connected refrigerant piping and refrigerant specialties are also certified and listed for use with the specific A2L refrigerant. Failure to do so will create a hazardous condition. Every part of an existing split system needs to be analyzed to determine if it can be reused in an R-454B and POE oil system:
  • Suction lines 2-5/8 OD and smaller type L copper are suitable for use with R-454B. Suction lines 3-1/8 OD must use type K or a thicker wall.
  • Discharge lines, liquid lines, heat pump vapor lines, hot gas bypass lines 1-3/8 OD, and smaller type L copper are suitable for use with R-454B. These same lines sized at 1-5/8 OD or 2-1/8 OD must use type K or thicker wall.
  • The installer is responsible for confirming that recycled refrigerant lines are clean of any contaminants that may impact compressor reliability.
NOTICEEquipment Damage!This is POE oil, which readily absorbs moisture. Always use new oil and never leave containers open to the atmosphere while not in use. All Codes take precedence over anything written here.Microchannel Heat Exchanger CondensersThe microchannel heat exchanger (MCHE) condenser design is quite similar to the design of an automobile radiator. Refrigerant is distributed to very small channels in thin plates. The plates are one above the other, separated by fins Figure 7. This design improves heat transfer and the refrigerant that enters the coil quickly turns to liquid. The MCHE tube volume holds very little refrigerant, so the refrigerant charge of the system is reduced. However, the tube volume is so small that if the flow of refrigerant out of the MCHE condenser is slowed much more than the flow of refrigerant into the MCHE condenser, the condenser may quickly fill with liquid and cause a high-pressure control trip. To avoid this condition, three system design requirements have been made on the RAUK unit with MCHE:
  • No pump-down: The storage capacity of the MCHE will not support pump-down. A liquid solenoid is still required and closes simultaneously as the circuit cooling shuts off.
  • No trim solenoid: The storage capacity of the MCHE will not support partial shut-off of the evaporator coil.
  • Bleed port TXVs: As the TXV modulates to find the proper superheat, the liquid restriction caused by the modulating of a non-bleed TXV can excessively slow the refrigerant. A bleed port TXV allows enough refrigerant to pass through the valve bleed port to prevent high-pressure issues.
Exception: The RAUK unit that uses braze plate chilled-water evaporators does not need a bleed port TXV. This type of evaporator doesn’t hold enough refrigerant to cause the high pressure issue described. Because of the low refrigerant volume, the control system does not need to pump down but will still require a liquid line solenoid for charge isolation.TRANE R-454B IntelliCoreTM Split Systems User Guide (9)Examples of Field-Installed Evaporator PipingSingle Circuit RAUK Systems Type UF Evaporator Coil with One Distributor
  1. Pitch the liquid line slightly — 1 in. / 10 ft cm / 3 m ) — so that the refrigerant drains toward the evaporator.
  2. Provide one expansion valve per distributor.
  3. Slightly pitch the outlet line from the suction header toward the suction riser — that is, 1 in. / 10 ft (1 cm / 3 m) in the direction of flow. Use the tube diameter that matches the suction-header connection.
  4. Use the DETINT to prevent oil and refrigerant migration when the unit is off. The DETINT also serves to isolate the TXV bulb from suction-header conditions. See “Line Sizing, Routing, and Component Selection,”
  5. For downflowing risers, use the horizontal tube diameter recommended in the Component selection table, found in Table 1,
  6. For vertical risers, use the vertical tube diameter recommended in the Component selection table, found in Table 1. Ensure that the top of the riser is above the evaporator coil.
  7. Pitch the suction line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  8. Insulate the suction line.
  9. Install a single isolation solenoid valve between the liquid-line filter drier and the sight glass.
Note: Due to reduced Microchannel condenser volumes, do not use “trim” solenoid valves.TRANE R-454B IntelliCoreTM Split Systems User Guide (10)Type UF Evaporator Coil with Two Distributors
  1. Pitch the liquid line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  2. Provide one expansion valve per distributor.
  3. Slightly pitch the outlet line from the suction header toward the suction riser — that is, 1 in. / 10 ft (1 cm / 3 m) in the direction of flow. Use the tube diameter that matches the suction-header connection. Use a double-elbow configuration to isolate the TXV bulb from other suction headers.
  4. Use the DETINT to prevent oil and refrigerant migration when the unit is off. The DETINT also serves to isolate the TXV bulb from suction-header conditions. See “Line Sizing, Routing, and Component Selection.
  5. For down-flowing risers, use one size smaller than the horizontal tube diameter recommended in the Component selection table, found in Table 1.
  6. For vertical risers, use the vertical tube diameter recommended in the Component selection table, found in Table 1. Ensure that the top of the riser is above the evaporator coil.
  7. Pitch the suction line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  8. Insulate the suction line.
  9. Install a single isolation solenoid valve between the liquid-line filter drier and the sight glass.
Note: Due to reduced Microchannel condenser volumes, do not use “trim” solenoid valves.TRANE R-454B IntelliCoreTM Split Systems User Guide (11)Type UF Evaporator Coil with Four Distributors
  1. Pitch the liquid line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  2. Provide one expansion valve per distributor.
  3. Slightly pitch the outlet line from the suction header toward the suction riser— that is, 1 in./10 ft (1 cm/3 m) in the direction of flow. Use the tube diameter that matches the suction-header connection.
  4. Use the DETINT to prevent oil and refrigerant migration when the unit is off. The DETINT also serves to isolate the TXV bulb from suction-header conditions. See “Line Sizing, Routing, and Component Selection.
  5. For downflowing risers, use one size smaller than the horizontal tube diameter recommended in the Component selection table, found in Table 1,
  6. For vertical risers, use the vertical tube diameter recommended in the Component selection table, found in Table 1. Ensure that the top of the riser is above the evaporator coil.
  7. Pitch the suction line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  8. Insulate the suction line.
  9. Install a single isolation solenoid valve between the liquid-line filter drier and the sight glass.
Note: Due to reduced Microchannel condenser volumes, do not use “trim” solenoid valves.TRANE R-454B IntelliCoreTM Split Systems User Guide (12)Dual Circuit RAUK SystemsType UF Evaporator Coil with Two Distributors
  1. Pitch the liquid line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  2. Provide one expansion valve per distributor.
  3. Slightly pitch the outlet line from the suction header toward the suction riser— that is, 1 in./10 ft (1 cm/3 m) in the direction of flow. Use the tube diameter that matches the suction-header connection.
  4. Use the DETINT to prevent oil and refrigerant migration when the unit is off. The DETINT also serves to isolate the TXV bulb from suction-header conditions. See “Line Sizing, Routing, and Component Selection.
  5. For down flowing risers, use one size smaller than the horizontal tube diameter recommended in the Component selection table, found in Table 1.
  6. For vertical risers, use the vertical tube diameter recommended in the Component selection table, found in Table 1. Ensure that the top of the riser is above the evaporator coil.
  7. Pitch the suction line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  8. Insulate the suction line.
  9. Install a single isolation solenoid valve between the liquid-line filter drier and the sight glass.
Note: Due to reduced Microchannel condenser volumes, do not use “trim” solenoid valves.TRANE R-454B IntelliCoreTM Split Systems User Guide (13)Type UF Evaporator Coil with Four Distributors
  1. Pitch the liquid line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  2. Provide one expansion valve per distributor.
  3. Slightly pitch the outlet line from the suction header toward the suction riser— that is, 1 in./10 ft (1 cm/3 m) in the direction of flow. Use the tube diameter that matches the suction-header connection.
  4. Use the DETINT to prevent oil and refrigerant migration when the unit is off. The DETINT also serves to isolate the TXV bulb from suction-header conditions. See “Line Sizing, Routing, and Component Selection.
  5. For down flowing risers, use one size smaller than the horizontal tube diameter recommended in the Component selection table, found in Table 1.
  6. For vertical risers, use the vertical tube diameter recommended in the Component selection table, found in Table 1. Ensure that the top of the riser is above the evaporator coil.
  7. Pitch the suction line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  8. Insulate the suction line.
  9. The top of the Circuit 1 suction riser must be higher than the bottom evaporator coil. Use the tube diameter recommended for a vertical rise in Table 1.
  10. The top of the Circuit 2 suction riser must be higher than the top evaporator coil. Use the tube diameter recommended for a vertical rise in Table 1.
  11. Install a single isolation solenoid valve between the liquid-line filter drier and the sight glass.
Note: Due to reduced Microchannel condenser volumes, do not use “trim” solenoid valves.TRANE R-454B IntelliCoreTM Split Systems User Guide (14)Type UF Evaporator Coil with Eight Distributors
  1. Pitch the liquid line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  2. Provide one expansion valve per distributor.
  3. Slightly pitch the outlet line from the suction header toward the suction riser— that is, 1 in./10 ft (1 cm/3 m) in the direction of flow. Use the tube diameter that matches the suction-header connection.
  4. Use the DETINT to prevent oil and refrigerant migration when the unit is off. The DETINT also serves to isolate the TXV bulb from suction-header conditions. See “Line Sizing, Routing, and Component Selection,.
  5. For down flowing risers, use one size smaller than the horizontal tube diameter recommended in the Component selection table, found in Table 1.
  6. For vertical risers, use the vertical tube diameter recommended in the Component selection table, found in Table 1. Ensure that the top of the riser is above the evaporator coil.
  7. Pitch the suction line slightly — 1 in. / 10 ft cm / 3 m) — so that the refrigerant drains toward the evaporator.
  8. Insulate the suction line.
  9. The top of the Circuit 1 suction riser must be higher than the bottom evaporator coil. Use the tube diameter recommended for a vertical rise in Table 1.
  10. The top of the Circuit 2 suction riser must be higher than the top evaporator coil. Use the tube diameter recommended for a vertical rise in Table 1.
  11. Install a single isolation solenoid valve between the liquid-line filter drier and the sight glass.
Note: Due to reduced Microchannel condenser volumes, do not use “trim” solenoid valves.TRANE R-454B IntelliCoreTM Split Systems User Guide (15)RAUK With Braze Plate Chilled-Water Heat ExchangerTXV for Remote ChillerPiping between the TXV and chiller, a braze plate heat exchanger (BPHE), must be 8 to12–inch long and the same size as BPHE inlet ID. Field supplied reducer(s) may be required at TXV. A bleed port valve is not required with brazed plate heat exchanger applications.Note: If necessary, install reducers at the TXV outlet. Do not install reducers at the braze plate evaporator.TRANE R-454B IntelliCoreTM Split Systems User Guide (16)Notes:
  • Shutoff valves are required for evaporator servicing.
  • The evaporator is shown for illustration purposes only.
  • Water inlet and outlet diameter and dimensional locations depends on unit size.
  • Water connections at the evaporator are grooved.
  • Field supplied 1/2” x 14 NPTE stainless steel or PVC plug required.
  • Locate freezestat and discharge temperature sensors close to the water outlet.
  • Install drain with shutoff valve at low point in leaving piping before system valve.TRANE R-454B IntelliCoreTM Split Systems User Guide (17)

Parts

Table 1. Component selection summary

UNITRAUK20RAUK25RAUK30RAUK40RAUK50RAUK60RAUK80RAUK100RAUK120
Refrigerant ckts111222222
Minimum step (tons)55.57.51011.715151520
SUCTION LINE
Tube diameter, horizontal and downflow (in.)1 5/82 1/82 1/81 5/82 1/82 1/82 1/82 5/82 5/8
Tube diameter, vertical upflow (in.)1 5/81 5/82 1/81 5/81 5/82 1/82 1/82 1/82 1/8
Filter shell 1/cktDHY01086FLR06122FLR06122DHY01086FLR06122FLR06122FLR06123FLR06124FLR06124
Filter core per shellELM03572ELM03572ELM03572ELM03572ELM03572ELM03572ELM03572ELM03572ELM03572
Access port 3/ckt(a)Schraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/coreSchraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/coreSchraeder valve w/ core
Frostat™ controlKIT01387KIT01387KIT01387KIT01387KIT01387KIT01387KIT01387KIT01387KIT01387
Ball valve 2/ckt (in.)VAL09077VAL09078VAL09078VAL09077VAL09078VAL09078VAL09078VAL06647VAL06647
LIQUID LINE
Tube diameter (in.)5/87/87/85/87/87/81 1/81 1/81 1/8
Filter shell 1/ckt(a)DHY01263DHY01263DHY01263DHY01263DHY01263DHY01263DHY01151DHY01151DHY01151
Filter core per shellCOR00102COR00102COR00102COR00102COR00102COR00102COR00102 (QTY 2)COR00102 (QTY 2)COR00102 (QTY 2)
Solenoid valve, coil 1/ ckt(b)VAL09133 COL01884VAL09133 COL01884VAL09100 COL01884VAL09133 COL01884VAL09133 COL01884VAL09100 COL01884VAL09135 COL01884VAL09135 COL01884VAL09485 COL12786
Sight glass 1/cktGLS00830GLS00831GLS00831GLS00830GLS00831GLS00831GLS00832GLS00832GLS00832
Access port 2/ckt(c)Schraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/coreSchraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/ coreSchraeder valve w/coreSchraeder valve w/ core
Ball valve 2/ckt (in.)(d)VAL07197VAL07198VAL07198VAL07197VAL07198VAL07198VAL07337VAL07337VAL07337
RAUK20RAUK25RAUK30RAUK40RAUK50RAUK60RAUK80RAUK100RAUK120
Note: Per ASHRAE 90.1 HGBP may not be more than 10 % for units less than 20 tons, and may not be more than 15% for units 20 tons and larger
  • (a) 7/8” connection size.
  • (b) For outdoor application, request junction box conduit boss, NEMA 4 watertight.
  • (c) Valve body VAL01483, valve core COR00006, valve cap CAP00072.
  • (d) Angle valves may be substituted for liquid line ball valves, 1 1/8 – VAL02336, 5/8 – VAL02475, 7/8 – VAL02575.
Table 2. Expansion valve selection, 20 to 60 ton MCHE (30% bleed)
Min TonnageMax TonnageManufacturerSelection(a)Trane Part
2.03.0SporlanBBIYE 1.5-CP (BP/30)VAL21647
2.53.5SporlanBBIYE 2.5-CP (BP/30)VAL21648
3.55.0SporlanBBIYE 3-CP (BP/30)VAL21469
4.57.0SporlanBBIYE 4.5-CP (BP/30)VAL21650
6.08.5SporlanBBIYE 6-CP (BP/30)VAL 21651
7.010.0SporlanBBIYE 7-CP (BP/30)VAL21652
8.013.5SporlanBBIYE 8.5-CP (BP/30)VAL21653
11.017.5SporlanBBIYE 11.5-CP (BP/30)VAL21654
Table 2. Expansion valve selection, 20 to 60 ton MCHE (30% bleed) (continued)
Min TonnageMax TonnageManufacturerSelection(a)Trane Part
14.021.5SporlanBBIYE 15.5-CP (BP/30)VAL21655
17.028.5SporlanOYE 20-CP (BP/30)VAL21657
22.030.0SporlanOYE 25-CP (BP/30)VAL21658
  • (a) Valve part numbers with “-ZGA” in place of “-GA”, may be used interchangeably.
Note: When sizing TXVs, select the TXV where the design tonnage is close to the middle of the device.Table 3. Expansion valve selection, 80 to 120 ton MCHE (15% bleed)
Min TonnageMax TonnageManufacturerSelection(a)Trane Part
2.53.0SporlanBBIYE 2.5-CP (BP/15)VAL21660
3.04.5SporlanBBIYE 3-CP (BP/15)VAL21661
4.06.0SporlanBBIYE 4.5-CP (BP/15)VAL21662
5.07.5SporlanBBIYE 6-CP (BP/15)VAL21663
6.09.0SporlanBBIYE 7-CP (BP/15)VAL21664
7.012.0SporlanBBIYE 8.5-CP (BP/15)VAL21665
9.515.5SporlanBBIYE 11.5-CP (BP/15)VAL21666
12.519.0SporlanBBIYE 15.5-CP (BP/15)VAL21667
15.025.0SporlanOYE-20-CP (BP/15)VAL21669
19.530.0SporlanOYE-25-CP (BP/15)VAL21670
23.545.0SporlanOYE-35-CP (BP/15)VAL21671
35.068.0SporlanOYE-55-CP (BP/15)VAL21672
(a) Valve part numbers with “-ZGA” in place of “-GA”, may be used interchangeably.Note: When sizing TXVs, select the TXV where the design tonnage is close to the middle of the device.Table 4. Expansion valve selection, any BPHE
Min TonnageMax TonnageSelection(a)Alternate
13.022.0OYE 20-CPn/a
17.026.0OYE 25-CPn/a
20.539.0OYE 35-CPn/a
30.559.0OYE 55-CPn/a
(a) Valve part numbers with “-ZGA” in place of “-GA”, may be used interchangeably.Table 5. R-454B lbs charge per 100 ft
ODSuctionLiquidDischarge
1/40.041.230.16
5/160.062.130.28
3/80.093.300.43
1/20.186.400.84
5/80.299.991.31
3/40.4315.001.97
7/80.5719.992.62
1 1/80.9834.084.47
1 3/81.4951.916.82
1 5/82.1173.489.65
2 1/83.67127.8316.78
2 5/85.65197.1125.88
Note: Type L or ACR tube. Suction: Saturated at 40°F, Liquid: Saturated at 90°F, Discharge: Saturated at 125°FMORE INFOTrane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy-efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or tranetechnologies.com.Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

Documents / Resources

TRANE R-454B IntelliCoreTM Split Systems [pdf] User Guide
R-454B IntelliCoreTM Split Systems, R-454B, IntelliCoreTM Split Systems, Split Systems

References

Documents - trane – R-454B

[pdf] User Manual Installation Guide Instructions Guide Label
Packaged Rooftop Air Conditioners 12 hours ago — Read this manual thoroughly before operating or servicing unit User Guide Foundation® Gas Electric 3 to 24 ore fa to RT SVU013A EN 07122024 trane content dam Trane Commercial global products systems equipment unitary rooftop foundation 15 25 tons |||
User Guide Packaged Rooftop Air Conditioners Foundation - Gas/Electric 3 to 5 Tons - 60 Hz Model Nu ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:34 filesize: 2.54 M page_count: 2 document date: 2024-03-27
[pdf] User Manual Installation Guide Instructions Label
Expansion Module Kits 13 sept 2024 — manual and on the tags stickers labels as well instructions below protection lockout tagout refrigerant handling etc Where local ACC SVN291A EN 09152024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Expansion Module Kits PrecedentTM Packaged Rooftop Units with SymbioTM 700 ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:33 filesize: 1.71 M page_count: 2 document date: 2024-09-09
[pdf] User Manual Installation Guide Instructions Parts List Accessories Label
Reference Enthalpy 1 day ago — manual and on the tags stickers labels as well instructions below Before installing servicing this unit technicians MUST put all PPE ACC SVN209E EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Reference Enthalpy FoundationTM Packaged Rooftop Units with Low Leak Econo ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:33 filesize: 2.29 M page_count: 2 document date: 2024-08-06
[pdf] User Manual Installation Guide Instructions Parts List Accessories Label
Comparative Enthalpy 2 giorni fa — Read this manual thoroughly before operating or servicing unit Safety Follow instruction same as downflow and secure RAE sensor to return air ACC SVN206D EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Comparative Enthalpy FoundationTM Packaged Rooftop Units with Low Leak Eco ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:32 filesize: 2.92 M page_count: 2 document date: 2024-08-06
[pdf] User Manual Installation Guide Label
Split System Air Conditioners Odyssey™ with Symbio™ Controls Aug 8 2024 — Use only approved leak detection methods per this instruction manual Compliance ASHRAE® Standard 15 2022 Application Engineering Manual APP APM001* EN SS SVX014A 08112024 elibrary tranetechnologies public commercial hvac Literature Installation Operation and Maintenance |||
Installation, Operation, and Maintenance Split System Air Conditioners OdysseyTM with SymbioTM Controls Cooling Condenser, R-454B 6 to 25 Tons 60 Hz TTA072K*A/D TTA090K*A/D TTA120K*C/D TTA150K*D TTA180K*C/D TTA240K*C/D TTA300K*C SAFETY WARNING Only qualified personnel should install and service t...
lang:en score:32 filesize: 6.56 M page_count: 44 document date: 2024-08-01
[pdf] User Manual Installation Guide Instructions Label
Precedent™ Packaged Rooftop Units 11 ago 2024 — Use only approved leak detection methods per this instruction manual The Follow all instructions in the unit s Installation Operation and RT SVX092A EN 08112024 elibrary tranetechnologies public commercial hvac Literature Maintenance |||
Installation, Operation, and Maintenance PrecedentTM Packaged Rooftop Units Cooling and Gas/Electric ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:31 filesize: 18.33 M page_count: 92 document date: 2024-08-09
[pdf] User Manual Installation Guide Guide Application Guide Label
Split System Air Conditioners Odyssey™ with Symbio™ Piping Application Guide Systems Symbio® Controls Trane Commercial HVAC SS APG017A EN 08112024 trane content dam global products systems equipment unitary split odyssey 6 to 25 tons |||
Application Guide Split System Air Conditioners OdysseyTM Tube Size and Component Selection TTA and ... is not a concern, as oil is miscible in liquid refrigerant at normal liquid-line temperatures. With R-454B refrigerant and POE oil, the pressure drop can be as high as 50 psid. 5 Overview Within the...
lang:en score:31 filesize: 1.39 M page_count: 32 document date: 2024-08-07
[pdf] Instructions Guide
Installer s Guide Replacement Coils Nov 21 2023 — These instructions do not cover all variations in systems nor provide for every possible contingency to be met connection with the installation 18 AH77D1 1A EN 11212023 elibrary tranetechnologies public residential hvac Literature Installation |||
18-AH77D1-1A-EN Installer s Guide Replacement Coils Includes coil models COL32491, 32492, 32493, 324 ... eld piping shall be checked for refrigerant leaks using an electronic leak detector calibrated for R-454B having a sensitivity of 5 grams per year or better. Note: Remove nitrogen pressure and repa...
lang:en score:30 filesize: 38.11 M page_count: 9 document date: 2023-11-21
[pdf] User Manual Installation Guide Instructions Parts List Label
ACC SVN232 EN book lanqc 0 to 100% Downflow Dry Bulb Economizer 15 sept 2024 — Installation Instructions manual 1 6 Rain diverter Table 2 Parts list This selection can be made using the Symbio service and installation mobile SVN232C 09152024 elibrary tranetechnologies public commercial hvac Literature |||
Installation Instructions 0 to 100 Downflow Dry Bulb Economizer PrecedentTM Packaged Rooftop Units ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:30 filesize: 2.44 M page_count: 12 document date: 2024-09-11
[pdf] User Manual Instructions
u114031 Installation and Operation Manual Condensing Units 30 ago 2023 — These instructions do not cover all variations in systems or provide for every possible contingency to be met connection with the installation 18 AC129D1 1B EN 08302023 elibrary tranetechnologies public residential hvac Literature |||
18-AC129D1-1B-EN Installation and Operation Manual Condensing Units 5TTR5018 060 ALL phases of this ... systems are maximum efficiency, optimum performance and the best overall system reliability. Note: R-454B refrigerant is an A2L refrigerant meaning: A = non-toxic, 2 = flammable, L = low burning ve...
lang:en score:29 filesize: 3.73 M page_count: 26 document date: 2023-08-31
[pdf] Guide
Untitled adp evaporator coil product guide di E COIL · Citato da 2 — Quick and easy installation in the field WHY bleed HP A C TXV B R32 Non See Spec Guide for additional nomenclature details optimized adpnow 2024 02 |||
EVAPORATOR COIL PRODUCT GUIDE NEW FOR 2024 ADPNOW.COM CONTENTS 04 WHY ADP 05 THE ADP ADVANTAGE 0 ... talled Refrigerant Detection System RDS Single RDS with dual-calibrated sensor for both R-32 and R-454B Field RDS offers one kit with everything needed to make an easy refrigerant change All ADP ...
lang:en score:29 filesize: 3.36 M page_count: 28 document date: 2024-02-16
[pdf] Guide
Untitled Evaporator Coil Product Guide de E COIL · Cité 2 fois — RE84960C210B2505AP sidharvey documents |||
EVAPORATOR COIL PRODUCT GUIDE NEW FOR 2024 ADPNOW.COM CONTENTS 04 WHY ADP 05 THE ADP ADVANTAGE 0 ... talled Refrigerant Detection System RDS Single RDS with dual-calibrated sensor for both R-32 and R-454B Field RDS offers one kit with everything needed to make an easy refrigerant change All ADP ...
lang:en score:29 filesize: 3.3 M page_count: 28 document date: 2024-05-06
[pdf] Guide
PRODUCT GUIDE Nov 6 2024 — Quick and easy installation in the field WHY ADP Page 4 Offering several options for flexibility air handlers are thoroughly tested to ensure adp handler product guide 2 adpnow 11 |||
PREMIER AIR HANDLERS PRODUCT GUIDE NEW FOR 2025 m F U R N A C E TM ADPNOW.COM CONTENTS 03 WHY ADP ... l, left or right horizontal V: Vertical E32 E33 ECM motor upflow/ etc. downflow 1: Piston R-454B R-32 A: R-454B Non-bleed HP-A/C TXV B: R-32 Non-bleed HP-A/C TXV C: R-454B Bleed HP-A/C TX...
lang:en score:29 filesize: 17.19 M page_count: 24 document date: 2024-11-15
[pdf] User Manual Installation Guide Instructions Label
Reference Enthalpy Standard Economizer 22 hours ago — Failure to follow instructions below could result in death or serious injury All Trane personnel must the company s Environmental Health and Safety ACC SVN201D EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Reference Enthalpy Standard Economizer FoundationTM Packaged Rooftop Unit ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:29 filesize: 916.19 K page_count: 2 document date: 2024-07-31
[pdf] User Manual Installation Guide Instructions Guide Application Guide Label
Tube Size and Component Selection 10 nov 2024 — Do not use non approved refrigerants refrigerant substitutes or additives WARNING Explosion Hazard! Failure to follow instructions below could SS APG018A EN 11102024 trane content dam Trane Commercial global products systems equipment unitary split rauj cauj 20 120 tons |||
Application Guide Tube Size and Component Selection IntelliCoreTM Split Systems 20 to 120 Tons R-454B Refrigerant Microchannel Condensers SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air...
lang:en score:29 filesize: 1.95 M page_count: 36 document date: 2024-11-05
[pdf] User Manual Installation Guide Instructions Guide Label
Hot Gas Bypass Kit 8 Aug 2024 — Failure to follow instructions below could result in death or serious injury All Trane personnel must the company s Environmental Health and Safety ACC SVN116H EN 08112024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Guide Hot Gas Bypass Kit OdysseyTM Split System Cooling Units with SymbioTM Controls, 6 to 25 Tons, R-410A/R-454B BAYHGBP010*: Used with All TTA***4* models BAYHGBP011*: Used with All TTA***K* models SAFETY WARNING Only qualified personnel should install and service the equipment. The ...
lang:en score:29 filesize: 6.51 M page_count: 20 document date: 2024-07-29
[pdf] Installation Guide Guide
Installer s Guide 18 BC116D1 1C EN 03262024 elibrary tranetechnologies public residential hvac Literature Installation |||
Installer s Guide TRANE Link Variable Speed Heat Pumps and Air Conditioners 5TWV8X24A1000A 5TWV8X3 ... ion only. Actual model may differ in appearance. Note: This unit is Link communicating only. Note: R-454B refrigerant is an A2L refrigerant meaning: A = nontoxic, 2 = flammable, L = low burning vel...
lang:en score:28 filesize: 3.2 M page_count: 36 document date: 2024-03-25
[pdf] User Manual Installation Guide Guide Label
Head Pressure Control Kit 2024 08 09 — The equipment described in this manual uses R 454B refrigerant which is flammable A2L Use ONLY rated service and components For specific 20 puslapių ACC SVN190C EN 08112024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Guide Head Pressure Control Kit OdysseyTM Split System with SymbioTM Controls, 13 to 25 ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:28 filesize: 5.2 M page_count: 20 document date: 2024-07-29
[pdf] Guide
ADP Image Downloads Advanced Distributor Products adp air handler product guide multi adpnow 2024 11 |||
PREMIER AIR HANDLERS PRODUCT GUIDE NEW FOR 2025 ADPNOW.COM CONTENTS 03 WHY ADP 12 MULTI-POSITION ... l, left or right horizontal V: Vertical E32 E33 ECM motor upflow/ etc. downflow 1: Piston R-454B R-32 A: R-454B Non-bleed HP-A/C TXV B: R-32 Non-bleed HP-A/C TXV C: R-454B Bleed HP-A/C TX...
lang:en score:28 filesize: 17.08 M page_count: 24 document date: 2024-10-09
[pdf] User Manual Installation Guide Instructions Guide Label
Split System Air Conditioners Odyssey™ with Symbio™ Controls R 454B Oct 18 2024 — Update to the Condenser and Handler Pairing Instructions table Added simplified wiring options for thermostat control constant two speed air SS SVN017B EN 10182024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Guide Split System Air Conditioners OdysseyTM with SymbioTM Controls R-454B Wiring and Start-Up SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be ...
lang:en score:27 filesize: 3.5 M page_count: 48 document date: 2024-10-10
[pdf] User Manual Installation Guide Instructions Label
Foundation Low Leak Economizer Horizontal LLE BAYECON354 ACC SVN205A EN 0 to 100% 15 hours ago — Consult thermostat s user manual for detailed instructions Figure 7 Mixed air temperature sensor installation 8 Mating connector plug removal Top SVN205D 07122024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions 0 to 100 Low Leak Economizer Horizontal Foundation Packaged Cooling and ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:27 filesize: 5.25 M page_count: 24 document date: 2024-04-01
[pdf] Installation Guide Instructions Guide
Installer s Guide 18 AD48D1 1A EN 08092024 elibrary tranetechnologies public residential hvac Literature Installation |||
Installer s Guide 18-AD48D1-1A-EN Cased Aluminum Coils Dedicated Upflow / Downflow Upflow / Dow ... FETY HAZARD This coil shall only be connected to an outdoor unit suitable for use with refrigerant R-454B. WARNING SAFETY HAZARD This appliance is not to be used by persons including children wi...
lang:en score:27 filesize: 4.87 M page_count: 24 document date: 2024-08-09
[pdf] User Manual Installation Guide Instructions Label
Voyager™ 3 9 mar 2024 — requirements of ANSI ASHRAE Standard 15 2022 the Maintenance section this manual for instructions Surface temperatures may exceed 300°F 150°C To RT SVX089A EN 03092024 elibrary tranetechnologies public commercial hvac Literature Installation Operation and |||
Installation, Operation, and Maintenance VoyagerTM 3 Packaged Rooftop Air Conditioners with SymbioTM ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:26 filesize: 9.93 M page_count: 104 document date: 2024-02-28
[pdf] User Manual Installation Guide Instructions Label
0 to 50% Manual Fresh Air Damper 1 giorno fa — Read this manual thoroughly before operating or servicing unit Safety advisories appear throughout as required Your personal safety and ACC SVN200C EN 07122024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions 0 to 50 Manual Fresh Air Damper Foundation Packaged Rooftop Units 3 to 5 ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:26 filesize: 1.04 M page_count: 2 document date: 2024-03-26
[pdf] User Manual
RT PRB040A EN 10302023 indd ASHRAE® 15 2022 A2L EDVC Example 30 ott 2023 — The following informational material is abridged from the Trane document APP APM001F Applications Engineering Manual Refrigeration Systems and elibrary tranetechnologies public commercial hvac Literature Sales |||
ASHRAE 15, 2022, A2L EDVC Example Multiple Zone VAV Packaged Rooftop Systems The following informa ... rooftop unit consists of two 10-ton 35-kW independent refrigeration circuits. The refrigerant is R-454B A2L and has a factory refrigerant installed detector. Each occupied space is served by a VA...
lang:en score:25 filesize: 645.12 K page_count: 2 document date: 2023-10-30
[pdf] Specifications Guide Warranty Label
HE Series Spec Guide SG 10 1 xlsx JM5061 adpnow 2024 04 |||
SG-HE-10 April 2024 Specification Guide HE Series Evaporator Coils Contents ........................ ... le 5 year warranty. 10 year Limited Warranty available. R-22, R-410A, AC Heat Pump compatible. R-454B, R-32, AC Heat Pump compatible with Refrigerant Detection System Kit. Refrigerant detectio...
lang:en score:25 filesize: 609.43 K page_count: 8 document date: 2024-04-30
[pdf] User Manual Installation Guide Guide Label
Electric Heaters cituojant I Guide · 2024 — Only qualified personnel should install and service the equipment The installation starting up servicing of heating ventilating 12 puslapių ACC SVN91L EN 08112024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Guide Electric Heaters Split System Air Handlers, 5-25 Tons BAYHTRR/BAYHTRT/BAYHTRS/BAY ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:25 filesize: 629.42 K page_count: 12 document date: 2024-07-29
[pdf] User Manual Installation Guide Instructions Label
Through the Base Electrical Utility Unit Mounted Disconnect Apr 1 2024 — Read this manual thoroughly before operating or servicing unit Trane advocates responsible Connect thermostat to terminal strip on front ACC SVN151E EN 04122024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Through-the-Base Electrical Utility/ Unit Mounted Disconnect Foundation Pa ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:25 filesize: 1.86 M page_count: 2 document date: 2024-02-14
[pdf] User Manual Installation Guide Label
Water Source Heat PumpAxiom™ Horizontal Vertical —GEH V* Pump Axiom™ Oct 25 2024 — Entering water temperatures range from 25°F to 120°F Leaving methods per this instruction manual The following leak detection WSHP SVX018B EN 10252024 elibrary tranetechnologies public commercial hvac Literature Installation Operation and Maintenance |||
Installation, Operation, and Maintenance Water Source Heat Pump AxiomTM Horizontal/Vertical -- GEH/V ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:25 filesize: 5.55 M page_count: 116 document date: 2024-10-22
[pdf] User Manual
ASHRAE Standard 15 2022 A2L EDVC Example Single Zone DX Split System 12 dic 2023 — Refer to the Trane application manual APP APM001* EN for more details environments through a broad portfolio of heating ventilating and air conditioning SS PRB004B 12122023 elibrary tranetechnologies public commercial hvac Literature Sales |||
engineering bulletin ASHRAE Standard 15-2022 A2L EDVC Example Single-Zone DX Split System The foll ... pace, with a 10-ft ceiling height. The split system consists of a single refrigeration circuit with R-454B A2L refrigerant. Supply air is ducted from the indoor airhandling unit AHU to four diffus...
lang:en score:25 filesize: 232.12 K page_count: 2 document date: 2023-12-12
[pdf] User Manual Installation Guide Instructions Label
0 to 50% Manual Outside Air Damper ACC SVN01R EN 09152024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions 0 to 50 Manual Outside Air Damper PrecedentTM Packaged Rooftop Units 3 to ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:25 filesize: 1.3 M page_count: 8 document date: 2024-09-12
[pdf] User Manual Installation Guide Instructions Label
ACC SVN285 EN fm lanqc 0 to 25% Manual Fresh Air Damper SVN285A 09152024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions 0 to 25 Manual Fresh Air Damper PrecedentTM Packaged Rooftop Units 12.5 t ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:24 filesize: 568.41 K page_count: 2 document date: 2024-09-12
[pdf] User Manual Installation Guide Instructions Guide Label
RT SVU015A EN 09152024 u210244 Packaged Rooftop Air Conditioners 1 giorno fa — SAFETY WARNING Only qualified personnel should install and service the equipment The installation starting up servicing of heating ventilating 21 hours ago Read this manual thoroughly before operating or unit Safety advisories appear throughout as required Your personal safety trane content dam Trane Commercial global products systems unitary rooftop foundation 15 to 25 tons |||
User Guide Packaged Rooftop Air Conditioners FoundationTM Gas 15 to 25 Tons - 60 Hz Model Numbers: ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:24 filesize: 1.7 M page_count: 2 document date: 2024-08-28
[pdf] Specifications Dimension Guide Guide Warranty Label
V Series Spec Guide SG VHC 19 xlsx JM5061 ADP Nominal 3 Ton Horizontal 17 5 Wide P13 A Coil Aluminum Non Bleed TXV siglers mw link id 12730 |||
SG-VHC-19 April 2024 Specification Guide V Series Premier Horizontal Evaporator Coils with Top Conne ... le 5 year warranty. 10 year Limited Warranty available. R-22, R-410A, AC Heat Pump compatible. R-454B, R-32, AC Heat Pump compatible with Refrigerant Detection System Kit. Refrigerant detectio...
lang:en score:24 filesize: 921.85 K page_count: 4 document date: 2024-04-30
[pdf] Specifications Guide Warranty Label
HE Series Spec Guide SG 10 1 xlsx JM5061 juin 2024 — High efficiency lanced fin design No hassle 5 year warranty Limited Warranty available R 22 410A AC Heat Pump compatible 394427 he hg series spec guide sg 06 d2yn8sruhmqjt4 cloudfront net userfiles documents inriver original |||
SG-HE-10-1 June 2024 Specification Guide HE Series Evaporator Coils Contents ....................... ... le 5 year warranty. 10 year Limited Warranty available. R-22, R-410A, AC Heat Pump compatible. R-454B, R-32, AC Heat Pump compatible with Refrigerant Detection System Kit. Refrigerant detectio...
lang:en score:24 filesize: 1.15 M page_count: 8 document date: 2024-06-12
[pdf] User Manual Installation Guide Instructions Label
Evaporator Defrost Control 9 hours ago — Read this manual thoroughly before operating or servicing unit Safety advisories appear throughout as required Your personal safety and ACC SVN185C EN 07122024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Evaporator Defrost Control Foundation Packaged Rooftop Units 3 to 5 Tons ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 4.5 M page_count: 2 document date: 2024-03-25
[pdf] Specifications
Spec Sheet Trane RunTru A5HP5036A1000A 3 Ton 15 2 SEER2 R 454B Heat Pump AM PRQ A5HP5036A 1A EN runtruhvac assets technical documents heat pumps a5hp5 |||
Submittal Split System Heat Pump A5HP5036A1000A Note: Graphics in this document are for representat ... R COIL TYPE ROWS F.P.I. FACE AREA SQ. FT. TUBE SIZE IN. REFRIGERANT CONTROL REFRIGERANT LBS. R-454B O.D. UNIT g FACTORY SUPPLIED LINE SIZE IN. O.D. GAS h i LINE SIZE IN. O.D. LIQ. CHA...
lang:en score:23 filesize: 1.23 M page_count: 5 document date: 2024-03-15
[pdf] User Manual Installation Guide Instructions Label
Barometric Relief Damper 2 days ago — Read this manual thoroughly before operating or servicing unit Warnings Cautions and Notices Safety advisories appear throughout as ACC SVN198C EN 07122024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Barometric Relief Damper Foundation Packaged Rooftop Units 3 to 5 Tons Mo ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 1.5 M page_count: 8 document date: 2024-03-26
[pdf] User Manual Installation Guide Instructions Label
Barometric Relief Damper 1 day ago — Read this manual thoroughly before operating or servicing unit Warnings Cautions and Notices Safety advisories appear throughout as ACC SVN198D EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Barometric Relief Damper FoundationTM Packaged Rooftop Units 3 to 5 Tons ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 1.51 M page_count: 8 document date: 2024-07-23
[pdf] User Manual Installation Guide Instructions Label
LP Conversion Kit 14 hours ago — Read this manual thoroughly before operating or servicing unit Safety advisories appear throughout as required Your personal safety and ACC SVN188C EN 07122024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions LP Conversion Kit Foundation Packaged Rooftop Units 3 to 5 Tons Model Num ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 1.3 M page_count: 2 document date: 2024-03-25
[pdf] User Manual Installation Guide Instructions Parts List Accessories Label
Barometric Relief Damper 2 days ago — Read this manual thoroughly before operating or servicing unit Safety advisories appear throughout as required Your personal safety and ACC SVN204F EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Barometric Relief Damper FoundationTM Units with Low Leak Economizer 3 to ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 2.2 M page_count: 2 document date: 2024-08-06
[pdf] Warranty
EDU SLB048 EN 03262024 trane content dam Trane Commercial north america us sales offices general |||
National Line Card Products Systems Solutions Approach Our goal is to deliver the outcomes that m ... electric heating and cooling; Symbio 800 controller; 140-230 tons cooling; 1500 - 2500 MBh heating; R-454B Ascend Model ACS Scroll Compressor; 140 - 230 Tons; R-454B; Heating and cooling capable; Heat...
lang:en score:23 filesize: 1.37 M page_count: 4 document date: 2024-03-26
[pdf] User Manual Installation Guide Instructions Parts List Accessories Label
0 50% Motorized Outside Air Damper 1 day ago — Read this manual thoroughly before operating or servicing unit Safety advisories appear throughout as required Your personal safety and ACC SVN197D EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions 0 - 50 Motorized Outside Air Damper FoundationTM Packaged Rooftop Units 3 ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 1.72 M page_count: 2 document date: 2024-07-23
[pdf] User Manual Installation Guide Instructions Label
Through the Base Gas and Electric Connections 2 days ago — Read this manual thoroughly before operating or servicing unit Safety advisories appear throughout as required Your personal safety ACC SVN189D EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Through-the-Base Gas and Electric Connections FoundationTM Packaged Roofto ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 1.19 M page_count: 2 document date: 2024-08-08
[pdf] User Manual Installation Guide Instructions Label
Electric Heat 1 day ago — Read this manual thoroughly before operating or servicing unit Warnings Cautions and Notices Safety advisories appear throughout as ACC SVN207D EN 08232024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Instructions Electric Heat FoundationTM Packaged Rooftop Units 3 to 5 Tons Model Numb ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 6.95 M page_count: 16 document date: 2024-08-13
[pdf] User Manual Installation Guide Guide Label
Head Pressure Control Kit Aug 11 2024 — Read this manual thoroughly before operating or servicing unit temperature falls below 50°F It reads discharge pressure from refrigeration ACC SVN194C EN 08112024 elibrary tranetechnologies public commercial hvac Literature Installation |||
Installation Guide Head Pressure Control Kit Odyssey Split System Cooling, 5 to 12.5 Tons LINE LOAD ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:23 filesize: 5.79 M page_count: 20 document date: 2024-07-29
[pdf] Warranty
National Line Card EDU SLB048 EN 09062024 trane br content dam Trane Commercial north america us sales offices general |||
National Line Card Products Systems Solutions Approach Our goal is to deliver the outcomes that m ... electric heating and cooling; Symbio 800 controller; 140-230 tons cooling; 1500 - 2500 MBh heating; R-454B Ascend Model ACS Scroll Compressor; 140 - 230 Tons; R-454B; Heat recovery; Symbio 800 control...
lang:en score:23 filesize: 1.43 M page_count: 4 document date: 2024-09-06
[pdf] User Manual Installation Guide Instructions Label
Split System Air Conditioners Odyssey™ with Symbio™ Controls Aug 11 2024 — Do not use non approved refrigerants refrigerant substitutes or additives WARNING Explosion Hazard! Failure to follow instructions below could SS SVX016A EN 08112024 elibrary tranetechnologies public commercial hvac Literature Installation Operation and Maintenance |||
Installation, Operation, and Maintenance Split System Air Conditioners OdysseyTM with SymbioTM Contr ... ions supersede these policies. Non-Trane personnel should always follow local regulations. WARNING R-454B Flammable A2L Refrigerant Failure to use proper equipment or components as described below c...
lang:en score:22 filesize: 2.94 M page_count: 56 document date: 2024-08-01
[pdf] Confidentiality Request Letter
Installation Operation Maintenance CG SVX039F GB 0524 tranebelgium files product doc 519 en ||| ||| Installation Operation Maintenance CGAF Air-Cooled Scroll Chillers CXAF Air to Water Scroll Heat Pumps 260 - 710 kW R-410A R-454B Refrigerant May 2024 CG-SVX039F-GB Confidential and proprietary Trane information Original instructions Table
Installation Operation Maintenance CGAF Air-Cooled Scroll Chillers CXAF Air to Water Scroll Heat Pumps 260 - 710 kW R-410A R-454B Refrigerant May 2024 CG-SVX039F-GB Confidential and proprietary Trane information Original instructions Table of Contents General Information3 Unit Description5 Unit...
lang:en score:22 filesize: 4.16 M page_count: 96 document date: 2024-05-24
[pdf]
HVAC Industry Update REFR PRB001F EN 05052020 trane content dam Trane Commercial global newsroom blogs |||
HVAC Industry Update Industry Consensus on HFC Refrigerants The industry continues to work through ... -410A, R-407C, R-123, R-404A, more... Reduced GWP ODP Lower GWP Solutions R-513A, R-32, R-452B, R-454B, R-466A, more... Lowest GWP ODP Ultra-Low GWP Solutions R-1234yf, R-1234ze, R-1233zd, R-1...
lang:en score:22 filesize: 2.69 M page_count: 2 document date: 2020-05-05

tags: IntelliCoreTM Split Systems, R-454B, R-454B IntelliCoreTM Split Systems, Split Systems, Trane,
TRANE R-454B IntelliCoreTM Split Systems User Guide (2025)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Twana Towne Ret

Last Updated:

Views: 5513

Rating: 4.3 / 5 (64 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Twana Towne Ret

Birthday: 1994-03-19

Address: Apt. 990 97439 Corwin Motorway, Port Eliseoburgh, NM 99144-2618

Phone: +5958753152963

Job: National Specialist

Hobby: Kayaking, Photography, Skydiving, Embroidery, Leather crafting, Orienteering, Cooking

Introduction: My name is Twana Towne Ret, I am a famous, talented, joyous, perfect, powerful, inquisitive, lovely person who loves writing and wants to share my knowledge and understanding with you.